Why does your peristaltic pump always go slow? (1)

Release date:Oct 18, 2023 Source:PreFluid Pageviews:-
After enjoying a happy holiday and returning to normal work and study, we will have a kind of "holiday syndrome", and there are many lazy times when the peristaltic pump is used, so how to solve it? Today, we will bring you a daily use of peristaltic pump Tips, please check!

After enjoying a happy holiday and returning to normal work and study, we will have a kind of "holiday syndrome", and there are many lazy times when the peristaltic pump is used, so how to solve it? Today, we will bring you a daily use of peristaltic pump Tips, please check!

PreFluid specializes in the development, production and sales of peristaltic pumps for more than ten years, according to their own technical experience and customer feedback, we summarized the following points for attention in the use of peristaltic pumps in order to improve their work efficiency and enthusiasm!

1. when the peristaltic pump is not used, loosen the pressure block. Peristaltic pump is through the pump head roller repeatedly squeeze the hose and the hose natural rebound to produce suction to achieve fluid delivery, want to maintain the service life of the pump tube, when the pump is not used, so that the pump tube is in a natural state of non-pressure.

2. choose the peristaltic pump to meet the customer flow requirements, as far as possible to reduce the pump speed to less than 300 RPM. The flow of the peristaltic pump is generated by the rotation of the pump head roller, and the faster the rotation, the shorter the service life of the pump tube.

3. pump head with special pipe, the rest of the connection pipe ordinary pipe. Extruded tubes need good compressive resilience and tear resistance, so these materials have higher purity, wall thickness and shape accuracy, and higher prices. Therefore, special tubes are used on the peristaltic pump to ensure the service life, and ordinary pipes are connected to make the whole system more economical and applicable.

4. the pump pipe inlet as short as possible, the pipe interface should not be lower than the caliber of the stuck pipe installed in the pump head. The suction of peristaltic pump is generated by the rebound of the pump pipe, if the inlet pipe is long or small, it will cause the suction end resistance, the rebound is blocked, and the actual flow of the transport will be greatly affected.

【Tag of this article】:Why does your peristaltic pump always go slow? (1)
【Editor】:PreFluidall rights reserved:https://www.prefluid.netPlease indicate the source

Related News

Principle and advantages of transmission peristaltic pump

Principle and advantages of transmission peristaltic pump

The transmission-type peristaltic pump works by taking advantage of the ability of a soft elastic tube to withstand defo...

Jul 25, 2023 Read Details
Precautions for the use of medical peristaltic pump

Precautions for the use of medical peristaltic pump

Medical peristaltic pump is a widely used equipment in clinical treatment, mainly used for accurate delivery of drugs, n...

Jun 01, 2023 Read Details
Microperistaltic pump

Microperistaltic pump

Microperistaltic pump is a kind of pump for conveying small flow liquid, which has the advantages of high flow accuracy,...

Mar 21, 2023 Read Details

Contact

  • Telephone: +86 13861019936
  • E-mai: pump@prefluid.com
  • Address:No. 8, Fuqiang Road, Xinbei District,
  • Changzhou City, Jiangsu Province

facebook Twitter linkedin youtube

Leave a Message

Copyright ©Changzhou PreFluid Technology Co., Ltd.. All rights reserved. ICP备案:苏ICP备12035203号-1 Privacy statementTerms & conditions Sitemap